Protocol
- Isolation
- Ideal: rubber dam
- Avoid contamination
- Cleaning
- Pumice or prophylaxis
- No organic residues
- Acid etching
- Phosphoric acid 35–37%
- Time: 15–30 seconds
- Rinse — 15 seconds
- Abundant water
- Remove all acid
- Dry — 15 seconds
- Air
- Appearance: frosted white
- Adhesive — according to manufacturer instructions
- Light curing
- According to manufacturer
- Proper light positioning
Key points
- Enamel must always be etched
- Frosted white = correct
- If not → re-etch
Common mistakes
- Not etching enamel
- Saliva contamination
- Insufficient time
- Not following manufacturer instructions
Expected result
- High bond strength
- Low leakage
- Clinical longevity